Peridata Repair and Support Centre, for free knowledge and advice.


Model PD-5010 (
Tandberg SLR100) Specifications


Navigation:
Tape Drives > SLR100Features > Specifications >
 

   

 

General Specifications

Drive

SLR100

Capacity (formatted)

Native/Compressed*

50GB/100GB*

Buffer Size

 

8MB

Data Transfer Rate

Native Sustained

5.0MB/s, 4.0MB/s, 3.0MB/s

 

Compressed Sustained*

10MB/sec (36GB/hr)

 

Compressed Sustained*

8.0MB/sec (28.8GB/hr)
 

Compressed Sustained*

6.0MB/sec (21.6GB/hr)

 

Burst

40MB/sec

File Access Time

Typical

89 sec

Media Load Time

Typical

<30 sec

System Interface

 

 SCSI-3 Multimode Wide Ultra (SE)Ultra2 (LVD) Note1

Drive Warranty

  3-years Factory

Format, Compatibility and Media

Recording Format

 

ALRF-1 (Advanced Linear Recording Format)

Encoding/Decoding

 

VR Note2 RLL

Number of Tracks

 

192 data tracks (+24 servo tracks)

Written Bit density

kfci

152.4

Backward Write

 

SLR100, SLR75, SLR60, SLR50, SLR40

Backward Read

 

SLR100, SLR75, SLR60, SLR50, SLR40, SLR32, SLR24, SLR7

Media

Media Data Retention

Archival Life

>20 years

Data Cartridges

 

PD-8510
    SLRtape100

Reliability and Error Correction

Hard Read Error Rate

  <10 Notes 1

Read Solomon ECC

  Level 10

Mean Time Between Failures (MTBF)

  300,000 hours

Mean Time To Repair
(MTTR)

  <30 minutes

Tape Motion

Tape Speed

Read/Write

52.5, 70.0 or 87.5 ins/sec auto selected depending on tape format and host transfer rate.

 

Wind/Rewind

103 ins/sec

Start Time

Typical at 86.2 ins/sec

380ms

Stop Time

Typical at 86.2 ins/sec

250ms

Dimensions

 

Internal Drive External Drive

 

 

 

Form Factor

Internal 5.25-inch half height (HH)

Height

1.732 ins (44mm) 2.5 ins (64.5mm)

Width

5.905 ins (150mm) 8.1 ins (205mm)

Depth

8.583 ins (218mm) 10.5 ins (267mm)

Weight

Internal External

 

 

2.4 lb (1.1kg) 5.7 lb (2.6kg)

Power Requirements Typical

Internal Drive

Power Consumption

 

 

 

+5V dc excluding
bus terminator

1.2A motor not running

+5V dc excluding
bus terminator

1.5A motor running

+12V dc Standby

100mA

+12V dc Running

1.3A
 

Standby

7.2 watts
 

Running

23.1 watts

Voltage Variations

 

+5V dc ±5%  125mV maximum ripple
  +12V dc ±10% 200mV maximum ptp ripple

Power Requirements

External Drive

Power Consumption

  100 to 240V ac / 0.6 to 0.3A, 50 to 60Hz

Environmental Specifications

Temperature

Operating

5°C to 40°C (41°F to 104°F)

 

Storage

-30°C to 60°C (-22°F to 140°F)

Relative Humidity

Operating

20% to 80%

 

Transport

5% to 95%

Maximum Wet Bulb Temperature

 

26°C (79°F)

Altitude

Operating

13,000 feet (4,000 meters)

 

Transport

40,000 feet (12,200 meters)

Regulatory Agency Approvals

 

 

UL 1950, CAN/CSA-C22.2 No. 950, EN 60950, IEC60950, AS/NZS 3548, EN 55022 (CISPR22);
FCC part 15 Class B, ICES-003, VCCI, EN55024,
CE, C-Tick
Note *  Assuming 2:1 data compression.
Note 1 Burst transfer rate is limited to 40MB/S (20 megatransfer)
Note 2 Internal drive ability to meet specifications is dependant on installation configuration.

 

Tandberg SLR100 Configurations

Item

Drive Kit Complete Solution

Drive

Internal External Internal External

CD Software Suite (with instruction manual on CD)

    yes yes

Internal SCSI Wide Cable with Termination (removable)

yes   yes  

External SCSI Cable

  yes   yes

External SCSI Terminator (LVD/SE)

  yes   yes

Data Cartridge

yes yes yes yes

Cleaning Cartridge

yes yes yes yes

Power Cable

  yes   yes

 

Tandberg Data Solutions
Drive

SLR100

Work Group Edition: ARCserve®2000 for
Windows 2000, NT and NetWare

Other operating system support:
Sun Solaris, AIX, SCO-Unix, UnixWare, UNIX, HP-UX, Linux
OS
Macintosh, Windows 98, NT Workstation
Note Complete solution available
Note OS Supported in operating system
Note Support available through other software
SLR100 Features 

 

 

 Tape Drives | Products | Accessories | Service  and Support

 

Peridata Communications Pty. Ltd.

3 Bertram Street, Mortlake. NSW Australia 2137

ABN 64 003 065 049

Phone:

+61 2 9736-3966

Fax:

+61 2 9736-3596

E-mail:

sales@peridata.com.au

 

information@peridata.com.au

Copyright © 1986 - 2007