General Specifications

Drive

SLR75

Capacity (formatted)

Native/Compressed*

35GB/75GB*

Buffer Size

 

8MB

Data Transfer Rate

Native

4.3MB/s

 

Compressed

8MB/s

File Access Time

Typical

<68 sec

System Interface

 

 SCSI-3 Multimode Wide Ultra (SE)Ultra2 (LVD)

Drive Warranty

  3-years Factory
Tape Alert Compliant   Yes
Head Life   10,000 hours

Format, Compatibility and Media

Recording Format

 

ALRF-1 (Advanced Linear Recording Format)

Encoding/Decoding

 

VR RLL

Number of Tracks

 

192

Backward Write

 

SLR75, SLR60, SLR50, SLR40

Backward Read
 

 

SLR75, SLR60, SLR50, SLR40, SLR24, SLR7, SLR5, SLR4

Media

Media Durability

Archival Life

>10 years

Data Cartridges

 

SLR75

Reliability and Error Correction

Hard Read Error Rate

less than

10^ -17

Read Solomon ECC

  Level 10

Mean Time Between Failures (MTBF)

  300,000 hours

Dimensions

 

Internal Drive External Drive

 

 

 

Form Factor

Internal 5.25-inch half height (HH)

Height

1.732 ins (44mm) 2.5 ins (64.5mm)

Width

5.905 ins (150mm) 8.1 ins (205mm)

Depth

8.583 ins (218mm) 10.5 ins (257mm)

Weight

Internal External

 

 

2.4 lb (1.1kg) 5.7 lb (2.6kg)

Power Requirements Typical

Internal Drive

Power Consumption

 

 

 

+5V dc excluding
bus terminator

1.2A motor not running

+5V dc excluding
bus terminator

1.5A motor running

+12V dc Standby

100mA

+12V dc Running

1.3A
 

Standby

7.2 watts
 

Running

23.1 watts

Voltage Variations

 

+5V dc ±5%  125mV maximum ripple
  +12V dc ±10% 200mV maximum ptp ripple

Power Requirements

External Drive

Power Consumption

  100 to 240V ac / 0.6 to 0.3A, 50 to 60Hz

Environmental Specifications

Temperature

Operating

5°C to 40°C (41°F to 104°F)

 

Storage

-30°C to 60°C (-22°F to 140°F)

Relative Humidity

Operating

20% to 80%

 

Transport

5% to 95%

Maximum Wet Bulb Temperature

 

26°C (79°F)

Altitude

Operating

13,000 feet (4,000 meters)

 

Transport

40,000 feet (12,200 meters)

Regulatory Agency Approvals

 

 

UL 1950, CAN/CSA-C22.2 No. 950, EN 60950, IEC60950, AS/NZS 3548, EN 55022 (CISPR22);
FCC part 15 Class B, ICES-003, VCCI, EN55024,
CE, C-Tick

 Tape Drives | Products | Accessories | Service  and Support

 

Peridata Communications Pty. Ltd.

3 Bertram Street, Mortlake. NSW Australia 2137

ABN 64 003 065 049

Phone:

+61 2 9736-3966

Fax:

+61 2 9736-3596

E-mail:

sales@peridata.com.au

 

information@peridata.com.au

Copyright © 1986 - 2007

 repair.centre@peridata.com.au